Search Results for "RhMSUS Online Training Materials 🐔 RhMSUS Test Questions 🏌 RhMSUS Test Questions 👿 Search for ➥ RhMSUS 🡄 and easily obtain a free download on ⮆ www.pdfvce.com ⮄ 🐹RhMSUS Latest Test Vce"

2011 18 Are Coriolis Mass Meters Suitable For Fiscal Liquid Applications Øiestad Intertek

[…] use of Coriolis meters. 3. API, Measurement Standards, chapter 5 – Metering, Section 6 – Measurement of Liquid Hydrocarbons by Coriolis Meters (2002, reaffirmed 2008) 4. VTM/Statoil training, Coriolis Mengdemålere 5. NFOGM nytt no 1/2006 og 2/2006 6. NSFMW 2006, Qualifying a Coriolis Condensate Export Metering station …., Trond Folkestad 7. NEL, Coriolis testing […] … Continue reading

1999 13 A High Accuracy, Calibration Free Multiphase Meter Miller Daniel

[…] the sound measurement principle of (multiple energy) gamma ray absorpti- on. The ultimate aim of such technology is to replace the measurement function of the tradi- tional test separator with a cheaper, lower-maintenance and calibration-free alternative. At present, due to its high-accuracy water-cut (WC) and real-time performance, MEGRA has also been utilised for well […] … Continue reading

1999 24 Square Root Error And Impulse Line Pulsation At CATS. Terminal Middlesbrough, UK Donoghue Amoco CATS Terminal

[…] at the CATS terminal. Both the newly installed skids, being EX1 and P1NTS as well as the original EX2 and EX3 skids were co- vered by the testing program and shown to be accurate at all rates in accordance with both the standard industry guidance and the CATS Measurement Manual (CMM). 317 Fig 2 […] … Continue reading

2001 12 Experience With Installation Of Ultrasonic Gas Flow Meters Under Severe Conditions Denstad Statoil

[…] their advantages over more traditional metering technologies such as orifice and turbines, and presented operational experiences. This paper will discuss experiences from one permanent installation and two test installations where the FMC Kongsberg Metering’s FMU 700/MPU 1200 technology has been subjected to severe conditions. At the Statoil operated Åsgard B platform in the North […] … Continue reading

2004 17 Installation Effects On Venturi Tubes Of Convergent Angle 10.5 Reader Harris NEL

[…] to the Venturi tubes. This pipe had previously been manufactured by boring out Schedule 80 pipe to the bore of a Schedule 40 pipe. For the baseline test there were lengths totalling 42D of machined pipe upstream of the Venturi tubes and a downstream machined length of 8D, where D is the diameter of […] … Continue reading

8 Sources Of Uncertainty In Measurement For Every Uncertainty Budget By Rick Hogan

[…] your measurement process to identify additional sources of measurement uncertainty. If you get stumped, do some research. Some great places to find sources of measurement uncertainty;  Online Search  Uncertainty Guides  Textbooks  Journal Articles  Conference Papers  Other Laboratories If you are still stuck after searching all of these information […] … Continue reading

2002 10 A New Ultrasonic Gas Flow Meter As A Base For A Natural Gas Energy System Dietz SICK

[…] samplers and calculator are widely used. The gas flow metering technology applied in such energy metering systems reaches from simple orifice plates, turbine meters to the la test technology ‘ultrasonic gas flow meters’. The system described here takes advantage of the low energy consumption of its components, which allows the system to be completely […] … Continue reading

2003 04 Venturi Meters In Wet Gas Flow Stewart National Engineering Laboratory

[…] unprocessed stream to be metered before co-mingling. Multiphase metering is also a valuable technology in well management, providing on-line information on the production flow; and in well testing, reducing the capital expenditure required to investigate potential new wells. Wet gas metering is at the high gas fraction end of multiphase metering, typically with a […] … Continue reading

2003 14 GE Panametrics Clamp On Flow Meter, Results In Industrial Gas Applications Ao GE Panametrics

[…] outlined. The meter creates no pressure drop, has a 100:1 turndown ratio and is useful for measurement of erosive, corrosive and toxic gas flow rates. Applications and test results for the meter on flow measurements of natural gas for re-injection to sub-sea well reservoirs, flow measurements of natural gas at a separator outlet, accuracy […] … Continue reading

2004 18 Determination Of Hydrocarbon Dewpoint From On Line Gas Chromatographic Analysis Pettigrew Daniel Europe Ltd

[…] dewscopes. It can be seen from this that a suitable instrument would offer significant CAPEX savings. Operationally, the use of a single instrument reduces spares holding and training requirements. Furthermore, TCD based process gas chromatographs are normally found to be robust and reliable. Compressed air is not required and only a minimum number of […] … Continue reading

2001 13 Operational Experience In Multiphase Metering Implementation Couput TotalFinaElf

[…] from manufacturer and in-house specialists, especially for fluid parameters (oil &water density) determination. The duration of the commissioning / start up phase was about 10 days including training for the operators. · As no test separator was available on the offshore platform for testing and verification; a static calibration procedure has been defined and […] … Continue reading

1998 D04 Ultrasonic Meters And Noise Bloemendaal Gasunie

[…] ofas much aspossi- ble USM's ofdifferent makesinthe vicinity ofapressure reducerandsimultaneous registration of the noise disturbance inamore systematic waythan hasbeen done uptillnow. Ithas not been theintention toperform acompetitive test,inother words toidentify 'tnebest meter" . • • 2 EXPERIMENTAL SET~UP 2.1 TestFacility The experiments describedinthis paper wereperformed inatest section atthe Gasunie labora- tory inGroningen. Thegasflows firstthrough […] … Continue reading

2004 09 Evaluation Of Flow Conditioners – Ultrasonic Meters Combinations Delenne Gaz De France

[…] to supplement the data available in the literature and to update the data base with regard to the most recent progress in ultrasonic meters technology. 2 THE TEST PROGRAMME The test programme has been defined to assess the ability of ultrasonic meters to handle flow perturbations based on experimental work. The performances of different […] … Continue reading

2007 07 A Prototype Wet Gas And Multiphase Flowmeter Johansen Weatherford Intl

[…] significantly lower impact on the total flow rate measured by Sonar. The Sonar-Venturi wet-gas flowmeter has been in development over the past several years and has been tested extensively in industry flow loops. Particular emphasis has been placed on developing a flowmeter with a broad operating envelope that includes a large span of fluid […] … Continue reading

2010 12 Developments In The Self Diagnostic Capabilities Of Orifice Plate Meters Skelton BP

[…] be shown that when the diagnostics signal a warning the patt ern of points can indicate extra information regarding the source of the problem. New CEESI Iowa test facility, BP Central Area Transmission System and C onocoPhillips Theddlethorpe gas terminal large orifice meter data sets are presented here showing these principles. 2. A Review […] … Continue reading

2011 20 Advanced Online Monitoring System & A Dirty Meter Model For Ultrasonic Gas Flow Meters Witte El Paso Pipeline Group

29 th International North Sea Flow Measurement Workshop 25 th – 28 th October 2011 Page 1 Further Developments In The Design & Implementation Of An Advanced Online Condition Based Monitoring System & A Dirty Meter Prediction Model For Custody Transfer Ultrasonic Gas Flow Meters James N. Witte – El-Paso Pipeline Group, Houston Te […] … Continue reading

2003 07 Wet Gas Allocation On The Canyon Express Project Cooley TotalFinaElf

[…] must be considered only as a last resort, a creative way to verify and, if possible, to calib rate each meter was needed. It was decided that online ca libration of individual subsea allo cation m eter s using the meters on the Canyon Station platform as reference was a viable approach. Making this […] … Continue reading

1999 07 Use Of Venturi Meters In Multiphase Flow Measurement Hall NEL

[…] Venturi meters spanning three diameter ratios and three inlet convergent angles was evaluated in the multiphase flow measurement facility at NEL. The multiphase flows used for the tests consisted of mixtures of stabilised crude oil, magnesium sulphate solution and nitrogen gas, across a range of test conditions. Multiphase test conditions are normally specified in […] … Continue reading

2003 12 Ageing Effects On Orifice Metering Reader Harris NEL

[…] conditioner may with time become partially blocked. Whereas orifice plates are regularly checked in service, flow conditioners are much less frequently checked. Therefore the first set of tests assessed the effects of rounding the upstream edge of a Zanker Flow Conditioner Plate and of blocking a row of holes in the plate. The Zanker […] … Continue reading

2007 04 Calibration And Verification Of Multiphase Meters For Allocation Metering Of The Urd Field Skårdalsmo SatoilHydro

[…] meter and the total Urd stream is measured in a topside multiphase meter at Norne. Furthermore it is possib le to route the Urd stream through a test separator with state of the art metering equipment. The oil from the “Svale” skid has high density and viscosity whereas the oil from the “Stær” is […] … Continue reading