NSFMW 1985 Technical Papers

1985 P aper No Paper Title Author Details Company Page 1 The Effects of Symmetric Steps and Gaps on Orifice Measurement Dr R G Teyssandier Daniel Industries 2 2 Performance of the Brooks Compact Prover on Air J Reid NEL 23 3 Experiences with Compact Prover On Live Crude Oil John Stokes Unitec Consultants […] … Continue reading

03 Challengs With Salinity Gryzlov

[…] initial development stage and ba sic theory behind sensor principles are given in . Currently, the sensor design and algorithm development work has been finalised. Several flow tests have been performed, which indicate that the developed sensor is capable of measuring conductivity of the water phas e for multiphase oil/gas/liquid flows and can improve […] … Continue reading

12 The Application Of Clamp On Ultrasonic Liprot

[…] carried out at an export metering point with well allocation according to calculation. Upstream conditions often combine the challenges of very thick -walled pipes in ex otic materials with wet gas at relatively low pressures. In the last few years non -invasive (clamp – on) ultrasonic flowmeters have be en installed on individual well […] … Continue reading

(5) Olafsen B Måleutfordringer Knyttet Til Tredjeparts Oppkopling Til Eksisterende Felt

[…] Allokering : – Partnere og Tie -in felter CO2 tax: – Fuel+flare+Diesel Tariffavtaler : – Vanninjeksjon – Gass løft – Prod.kapasitet – Topside MPFM kalibrering etc – Test by difference Operations: – Produksjonsbooking – Swivel kapasitet – Produksjons optimalisering – Flowlinje ruting – Brønntester (manifold ruting ) Lab: – Sampling & analyse – PVT […] … Continue reading

(1) Hansen Vegard Oppfølging Av Flerfasemålere I Drift

[…] ASA Oppfølging av flerfasemålere i drift …en presentasjon med diverse drypp fra Statoil med blanding av «gammelt nytt» og nyere erfaringer innen drift av flerfasemålere (inkludert design for å optimalisere senere drift) Innhold: • Design: Prosess – Kommunikasjon – Usikkerhet – PVT • Igangsetting • Oppstart • Drift: Styringsverktøy – Prøvetaking – Verifisering • […] … Continue reading

(2) Fonnes Daniel G Virtuell Måling Hva Er Det Egentlig

[…] 2 3 9 Virtual Flow Metering  Characterizing virtual flow metering  Metering principle  Maintenance and tuning  Applications areas 10 Virtual flow metering – Well testing � liquid Test alternatives: A. Test separator test B. Deduction test P/T P/T P/T 1 000 -3 000 m 5.0 m � = �� (�1,��1,�2,��2,�3,��3,�ℎ�� ���� […] … Continue reading

1985 01 The Effects Of Symmetric Steps And Gaps On Orifice Measurement Teyssandier Daniel

Lecturer:Mr.R.G.Teyss andier Daniel Industries Inc .- NorskeSivilingeni0rers Forening NORTH SEAFLOW METERING WORKSHOP Stavanger. 5-7November 1985 • TheEffects ofSymmetric Stepsand Gaps onOrifice Measurement I I, • Allrights reserved NIFand theAuthor 1 THE EFFECTS OFSYMMETRIC STEPSANDGAP5 ONORIFICE MEASUREMENT* Dr. R.6. Teyssandier Daniel Industries Inc. INTRODUCTION • Recesses orprotrusions withinthene~r flow field oforifice meters canbefound inalimited thoughsignificant […] … Continue reading

1987 04 Design And Suggestions To Reduce The VoS Effect For Gas Density Measurement Leibe Bopp & Reuther GmbH

…. _. ‘• NORWEGI AN SOCIETY OF CHARTERED ENGINEERS NORTH SEA FLOW METERING WORKSHOP 13 – 15 October 1987 Stavanger Forum, Stavanger DESIGN AND SUGGESTIONS TO REDUCE THE VOS EFFECT FOR GAS DENSITY MEASUREMENT Lecturer: Project Engineer K. Leibe, Bopp & Reuther GmbH. West-Germany All rights reserved N IF and the Author – 1 […] … Continue reading

1988 18 Operating Experience With A Compact Prover I Ross Caleb Brett International Ltd

[…] packing case,which Ls carried insidethecontrol cabin. Shouldanyofthe seals break, as with anycertified device,thenthevessel must be recalibrated and resealed. Itcan beseen thatthisvessel nrustbetreated withgreat care. Should thevessel becomedentedorsome materials becometrapped Ln s Lde , then itisobvious thatthevolume readonthe scale would increase. Theonly wayforthevolume todecrease isif something is removed fromtheinside, i.e.ifthe vortex splitting weirwasremoved. Since theoriginal […] … Continue reading

1992 14 A New Multi Path Ultrasonic Flow Meter For Gas Lygre CMR

[…] I • 10′” North SeaFlow Measurement Wotbhop CONTENTS Page 1 INTRODUCTION 1 2 MEASUREMENT PRINCIPLE 2 3 SYSTEM DESCRIP’IlON 4 4 FLOW METER PERFORMANCE 6 4.1 Calibration tests 6 4.2 Flow analysis 9 • 5 SPECIAL FEA1URES 14 6 PROVING 15 6.1 Zero calibration 15 6.2 Flow calibration 16 6.3 Self diagnostics 16 6.4 […] … Continue reading

1994 08 The Gallagher Flow Conditioner Gallagher Shell

2·~ • TIlE G ALLAGHER FLOW CONDITIONER James E. Gallagher, P.E. – Shell USA Paul J. LaNasa – CPL & Associates Ronald E. Beaty, P.E. – Amoco Production This paper describes the design theory, third party research results and pending evaluations for the Gallagher Flow Conditioner (GFC). Experimental results for the GFC indicate a […] … Continue reading

1995 22 A Performance Study Of A V Cone Meter In Swirling Flow Shen Chevron

[…] Workshop 1995 Paper 20: Main Index ‘ A PERFORMANCE STUDY OF AV CRONE METER IN SWIRLING FLOW Authors: J .S. Shen, Chevron Petroleum Techn. Co, USA J.Bosio and S. Larsen, K-Lab/Statoll, Norway Organiser: Norwegian Society of Chartered Engineers Norwegian Society for Oil and Gas Measurement Co-organiser: National Engineering Laboratory, UK Reprints are prohibited uni~ […] … Continue reading

1996 09 Importance Of Calculating Permittivity And Conductivity In Mixtures Of Liquids Hammer University Of Bergen

1996 09 Importance Of Calculating Permittivity And Conductivity In Mixtures Of Liquids Hammer University Of Bergen

1997 17 Testing Of Noise Suppression System For Multipath Ultrasonic Gas Flow Meters Kristensen Kongsberg Offshore

Main Index NSFMW.97 North Sea FL Measurement Workshop Paper ‘Pf: TESTING OF NOISE SUPPRESSION SYSTEM FOR MULTIPATH ULTRASONIC GAS FLOW METERS Authors: Bard Dybwad Kristensen and Cecilie Lofsei, Kongsberg Offshore AS, Norway Kjell-Eivind Freysa, Christian Michelsen Research AS, Norway Organiser: Norwegian Society of Chartered Engineers Norwegian Society for Oil and Gas Measurement Co-organiser: National […] … Continue reading

1997 24 Disturbed Flow Profiles And Their Effect On Gas Meter Behaviour Wendt PTB

[…] metering installations , turbine meters , ultrasonic and electromagnetic flowmeters , or vortex flow­ meters ). Jn some cases the measuring errors due to the flow disturbances tested are described as of a remarkable order of up to 5 % for orifice and turbine meters or of up to 11 % for ultrasonic flowmeters […] … Continue reading

2002 D03 Novel Level Controls And Resulting Performance Enhancement Marrelli ChevronTexaco

Session 5 Discussion Paper No 2 Use of Multiphase Meters in Process Control for Oil Field Well Testing: Novel Level Controls and Resulting Performance Enhancement Jack Marrelli, ChevronTexaco Ram Mohan, Shoubo Wang; University of Tulsa North Sea Flow Measurement W orkshop 22 nd – 25 th October 2002 1 Use of Multiphase Meters in […] … Continue reading

2004 12 ALTOSONIC III – A Dedicated Three Beam Ultrasonic Flowmeter Hogendoorn KROHNE

[…] and refined liquid hydrocarbons. This paper describes: • technical developments regarding ultrasonic flow metering; • a new concept for proving ultrasonic flow meters; and • results of tests performed in the field with ultrasonic flowmeters. 2. TECHNICAL IMPROVEMENTS OF THE ULTRASONIC FLOWMETER FOR CUSTODY TRANSFER 2.1 Improvements in accuracy and stability Significant improvements in […] … Continue reading

2005 07 Reciprocity And Its Utilization In Ultrasonic Flow Meters Lunde CMR

[…] significantly affecting the accuracy at the high velocity measurements. The AGA-9 report and the API MP MS Ch. 5.8 standard both prescribe need for “zero flow verification test (zero test)” or “zeroing the meter”, for gas and liquid USMs, respectively. Advances in USM technology based on the electroacoustic reciprocity principle have provided methods for […] … Continue reading

2006 D03 Traceable Calibration Of Liquid Densitometers Glen TUV NEL

[…] pressures using transfer-standard fluids characterized in the Primary Liquid Density Facility. Results from each densitometer will be assessed for accuracy and stability across the range chosen. The test programme will investigate the influence of fluid properties (density and viscosity), densitometer temperature and pressure on the calculated densities provided by the densitometers. The calculated density […] … Continue reading

2007 21 Flare Metering With Optics From Blue Sky Technology To The Real World Parker ConocoPhillips

[…] ever. In reality, this is far from true, as at least one vendor of such devices has developed its technology to the point that laboratory and field testing have been carried out, and more than twenty-five units have been sold and installed into operational plants. The purpose of this paper is to review the […] … Continue reading