2004 16 APIās Microprocessor Based Flowmeter Testing Programme Elliott Omni Flow Computers
Paper 5.4 APIās Microprocessor Based Flowmeter Testing Programme Kenneth Elliott Omni Flow Computers Inc North Sea Flow Measurement Workshop 26-29 October 2004 1 APIās Microprocessor Based Flowmeter Testing Programme Mr. Kenneth D. Elliott Omni Flow Computers Inc. 1 INTRODUCTION Modern microprocessor based flowmeter technologies for measuring liquids, such as Coriolis meters, and Ultrasonic flowmeters […] … Continue reading
11 Coriolis Density Error G Lindsay TUVNEL
[…] calculation by ambient temperature can be live corrected by repurposing existing diagnostic measurements on the device transmitter . Therefore, using the high -resolution data sets obtained during testing , a new correction model was d eveloped and validated by way of blind testing. The new model is shown to work on both ag eing […] … Continue reading
16 How To Reduce OPEX Bruno Pinguet, TUVNEL
[…] fee to ensure the technologyās performance over time without being able to independently assert the MPFMās actual or field performance, requiring the end-user to conduct their own tests to determine the MPFMās true field performance. How do we address the in situ of MFPM performance? There are two methods that can address this. The […] … Continue reading
07 Possible Installation Effect On Density Meter In A Fastloop TechnipFMC
[…] by introducing a āsmart component installationā. This has involved stacking of instrumentation and introduction of assembly blocks to reduce space and installation time. Introduction During assembly and testing of a fast loop system we observed readings from the density meters with periodic anomalies. Further examinations were executed on different fast loop systems to collect […] … Continue reading
2017 07 Possible Installation Effect On Density Meter In A Fastloop SmĆørgrav TechnipFMC
[…] by introducing a āsmart component installationā. This has involved stacking of instrumentation and introduction of assembly blocks to reduce space and installation time. Introduction During assembly and testing of a fast loop system we observed readings from the density meters with periodic anomalies. Further examinations were executed on different fast loop systems to collect […] … Continue reading
2005 11 Wet Gas Measurement In The Southern North Sea Geach ConocoPhillips
[…] impinging on the meter convergent section. ā¢ Calibration repeatability over time ā¢ The methods used to correct the over-reading (namely Murdock, Chisholm and de-Leeuw). ā¢ Flow verification tests carried out on two meters installed in the Southern North Sea. ā¢ First, a sub sea meter located some 34km from the host platform. This not […] … Continue reading
04 Field Performance Evaluation Of A Non Radioactive MPFM, In The Middle East ABBON KOC SGS
[…] and a cquiring correct fluid parameters for each well during rig -up is fundamental for measuring the flow rates accurately. With the right tools , preparation and training, the ABBON field engineer managed to provide the necessary fluid measurements for an efficient commissioning , data logging and reporting . 2. The test separator gas […] … Continue reading
2017 04 Field Performance Evaluation Of A Non Radioactive MPFM In The Middle East Harstad ABBON
[…] and a cquiring correct fluid parameters for each well during rig -up is fundamental for measuring the flow rates accurately. With the right tools , preparation and training, the ABBON field engineer managed to provide the necessary fluid measurements for an efficient commissioning , data logging and reporting . 2. The test separator gas […] … Continue reading
1995 15 Fluenta Multiphase Flow Meter, Tested And Marinised Olsvik Fluenta
North Sea Measurement Workshop 1995 Paper 19: Main Index ‘ FLUENTA MULTIPHASE FLOW l.IBTER, TESTED AND MARINISED Authors: Kenneth Olsvik and Tor Widerae Fluenta, Norway Organiser: Norwegian Society of Chartered Engineen Norwegian Society for Oil and Gas Measurement Co-organiser: National Engineering Laboratory, UK Reprints are prohibited uni~ permission from the authors and the organisers […] … Continue reading
2008 03 Infrared Water Cut Meter For Cost Effective Individual Monitoring Of Complex Wells Al Saiyed Saudi Aramco
[…] by providing the data to timely implement corrective action. Methods for measuring water-cut values range from conventional hand sampling to cutting edge technology. Saudi Aramcoās traditional well testing practices, utilizing a test trap at a GOSP, limit the information available, due to the infrequent test trap availability on a per well basis, usually exceeding […] … Continue reading
1997 07 Revised DTI Guidelines For Petroleum Measurement Griffin DTI Oil & Gas Office
[…] revised and enlarged. The new guidelines cover a much wider scope of measurement situations than before. Included in the new issue is guidance on allocation measurement, well testing , multiphase flow measurement, new technology acceptance procedures and operating procedures for different types of measurement systems. Significant changes have taken place in recent years both […] … Continue reading
2010 14 Field Comparison Of A Mechanical And Electronic Custody Measurement Loop For Hydrocarbon Liquids Salim Aramco
[…] measurement functions. 2 PHASE 1 TESTING OF ULTRASONIC METER Initial tests conducted on this technology were with a turbine and a single ultrasonic meter connected to an online prover. The setup was designed to perform synchronized batching and proving. The control signals for starting and ending batches and proving was with the turbine meter/prover […] … Continue reading
1993 20 Testing Water In Oil Monitors At The Mongstad Terminal Ćkland Statoil
NORWEGIAN SOCIETY OF CHARTERED ENGINEERS NORWEGtAN soc1m IOR Oil AND GAS MEASUREMENT NORTH SEA FLOW MEASUREI.fENT WORKSHOP 1993 26 -28 October, Bergen Testing water-in-oil moniton at the Mongstad tenninal by Mr. Ole 0kland, Statoil Research Centre, Trondheim Mr. Hans Berentsen, Staton technology division, Stavanger Mr. 0ivind Olsen, Staton Research Centre, Trondheim Reproduction is prohtl>ited […] … Continue reading
07 Flow Measurement Of High Mills
[…] PHDVXUHPHQW WHFKQRORJLHV VXFK as Coriolis and XOWUDVRQLFGHYLFHV&RQIXVLRQFDQDULVHZKHQIORZPHWHUPDQXIDFWXUHU?VPDNHVSHFLILF claims on performance with little independent and verifiable d at a published. This follows partly from the scarcity of suitable test facilities capable of p roviding viscous flow in combin at ion with accur at e and traceable reference instrument at ion. To improve this situ at […] … Continue reading
2013 07 Flow Measurement Of High Viscosity Fluids Mills NEL
[…] PHDVXUHPHQW WHFKQRORJLHV VXFK as Coriolis and XOWUDVRQLFGHYLFHV&RQIXVLRQFDQDULVHZKHQIORZPHWHUPDQXIDFWXUHU?VPDNHVSHFLILF claims on performance with little independent and verifiable d at a published. This follows partly from the scarcity of suitable test facilities capable of p roviding viscous flow in combin at ion with accur at e and traceable reference instrument at ion. To improve this situ at […] … Continue reading
1995 16 Wellcomp Multiphase Flow Meter Golike Occidental Petroleum
North Sea Measurement Workshop 1995 Paper 21: Main Index WELLCOMP MULTIPHASE FLOW METER -Oxy field experience with replacement of traditional well test separators Authors: Curd Golike, Occidental Petroleum,USA Dave Cardellini, Paul Munroe -WellComp, USA Fernando Albuja, Occidental, Equador Organiser: Norwegian Society of Chartered Engineers Norwegian Society for Oil and Gas Measurement Co.organiser: National Engineering […] … Continue reading
2018 11 Blind Testing Of Non Radioactive Multiphase Metering Systems By The Joint
[…] one MPFM per well would lead to relatively high costs. Moreover, the use of permanent gamma sources may limit large deployment due to the requirement of authorization, training and follow -up for safety and security reasons. Therefore the need for cheaper metering solutions has been addressed and several solutions can be envisaged: ā¢ Simplified […] … Continue reading
2005 21 Allocation The Howe Measurement Challenges Tierney Shell
[…] allocation between the different ownerships, as opposed to traditional separator metering. This paper will present the journey of the project activity through the selection criteria, flow loop test, installation, commis sioning and the first 3 months of operation of the MPFM including verification with the Nelson test separator. Detailing with careful management and engineering […] … Continue reading
1989 11 Field Based Water In Oil Sampling Studies King NEL
[…] WORKSHOP Rica Maritim llotcl, Hnugesund October 24-26, 1989 “Field-based Water-in-Oil Sampling Studies” Lecturer: Nicholas W. King National Engineering Laboratory Reproduction is prohibited without written permission from NIF and the author S U M M A R Y FIELD-BASED WATER-IN-OIL SAMPLING STUDIES by Nicholas W King The paper describes the water-in-oil sampling field tests performed […] … Continue reading
2003 25 Phase Watcher VX Multiphase Flowmeter Heidrun Experience And Analysis Moksnes Framo
[…] on the platform. Much effort has been devoted to explain the influence of uncertainties in PVT data on the metrological mu ltiphase flowmeter performance. Finally, some early test results are compared with corresponding test separator data. The conclusion is that the multiphase flowmeters function as intended, however, lack of PVT data has delayed the […] … Continue reading