Inglis Gordon, Allocation For CCUS Hubs

[…] 2 | Accord Allocation for CCUS Hubs Agenda ‱ What is a CCUS Hub? ‱ What drives the need for Allocation? ‱ Where do we Allocate? ‱ Questions? | 3 | Accord What is a CCUS Hub? ‱ A CCUS Hub receives Carbon Dioxide (CO 2) from emitting sources and transports it to storage […] … Continue reading

Inglis Gordon, Allocation For CCUS Hubs

[…] 2 | Accord Allocation for CCUS Hubs Agenda ‱ What is a CCUS Hub? ‱ What drives the need for Allocation? ‱ Where do we Allocate? ‱ Questions? | 3 | Accord What is a CCUS Hub? ‱ A CCUS Hub receives Carbon Dioxide (CO 2) from emitting sources and transports it to storage […] … Continue reading

1989 14 Auditing The Management Of Measurement Britton BP

[…] as they provide the approved basis for performing given tasks. Witnessing an offshore Technician actually performing the tasks is essential. The Technician’s knowledge of the procedures, job training, adequacy of documentation and record keeping all become quickly evident. If a Technician’s performance is not entirely satisfactory, it should not be viewed as a failing […] … Continue reading

1997 06 Measurement Strategies For Downhole Multiphase Metering Hammer University Of Bergen

[…] were accurately determined for relatively simple flow regimes. One attractive feature of combining neural networks and system models, is that the model can be used to generate training data for the network at differ­ ent conditions. This, which of course requires accurate (and verified) models, simplifies the use of neural networks which otherwise could […] … Continue reading

Nytt Fra NFOGM 3 2003

[…] er tilgjengelig for alle og ogsĂ„ noe som kan brukes av skoler/hĂžyskoler. FĂžlg med, kanskje vi kan si noe mer i neste nummer av Nytt fra NFOGM. TEST SLØYFE FOR FLERFASE PÅ KÅRSTØ Av Stein Larsen, Statoil K-lab, KĂ„rstĂž mĂ„le- og teknologi- laboratorium har utvidet sitt testanlegg til Ă„ inkludere en testslĂžyfe for flerfasemĂ„ling. […] … Continue reading

Nytt Fra NFOGM 4 2005

[…] sikre at de fiskale mĂ„linger har den kvalitet som kreves. Arbeidet utfĂžres gjennom deltakelse i PUD-arbeid (PUD – Plan for utbygging og drift), oppfĂžlging av design og testing av utstyr og ved oppfĂžlging av drift av mĂ„leutstyr pĂ„ produksjons og losseinnretninger offshore og terminal anlegg pĂ„ land. OppfĂžlgingen av design og drift utĂžves ved […] … Continue reading

Kalibrering Av Flow MÄlere Og Provere For Fiskalt Bruk @OØ 2012

[…] -kalibrering. Observasjon / Ettertanke Med de beskrivelsene og betraktningene som er gitt ovenfor, sĂ„ kan det til slutt ogsĂ„ vĂŠre grunn til Ă„ stille spĂžrsmĂ„l ved at test separatorer rundt omkring i NordsjĂžen, sĂ„ vidt vi kjenner til , ikke har fokus pĂ„ dette. Test separatorer brukes ogsĂ„ mot allokeringsmĂ„linger ifm flerfasekalibrering og burde […] … Continue reading

Measuring Produced Reserves Of Heavy Oil By Use Of MPFM

[…] application in the last 14 years. The list is made up by successful te st and field installations. 5 Field Experience  98-99 First extensive flow loop test to qualify ve nturi in combination with multi-energy gamma – (Cepro) SPE 63118  2000 Commercialization of venturi sizes of 52mm and 88 mm – Viscosity […] … Continue reading

Installasjonskrav Ved Fiscal Gass MĂ„ling (2)

[…] rĂžr konstruksjoner med eller uten FC, som ikke pĂ„virker pĂ„krevd usikkerhet. Dette skal gjelde for alle flowrater mellom Qmin og Qmax. Des ignet ska l supporteres med test data. 2. Spesifisere maksimalt tillatt flow -forstyrrelse oppstrĂžms mĂ„leren som ikke pĂ„virker mĂ„leren utover pĂ„krevd usikkerhet. Dette skal gjelde for alle flowrater mellom Qmin og Qmax. […] … Continue reading

06 OD JV Sammenligning Av Lab PrĂžver, Vann I RĂ„olje V Gunn Kristin Svendsen, Justervesenet

[…] fĂŠrre) vanninnhold fra 0,1 volum% til 3,1 volum% vann i rĂ„oljen ‱ PrĂžvene ble laget til pĂ„ Hydros laboratorium pĂ„ Sture terminalen – har ogsĂ„ utfĂžrt stabilitets test og densitetmĂ„ling ‱ Det nye med Ă„rets SLP var at all rapportering skjedde via Internett. Stort sett var alle fornĂžyd med denne lĂžsningen. Oppslutning – antall […] … Continue reading

05 Et Produkt LeverandĂžrs Syn Frode Endresen

[…] uncertainty Critical Factor: Increasing Cross -talk due to Attenuation 25 25 Solution: ïŹ Improved transducer decoupling ïŹ Isolating transducers from meter tube, reducing direct metallic contact ïŹ Tests performed on a flow meter tube using crude oil with a viscosity of 1,500 cSt ïŹ R&D test results prove that the signal to noise (cross […] … Continue reading

05 S Fosse Informasjon Fra Prosjekter I ODs Regi

[…] . med flow profil) ‱ Kontroll pĂ„ flow regime ‱ Scaling og voks effekter minimeres ‱ Dupliserte transmittere for T, P og dP . ‱ Kalibreringsreferanse mot test separator eller om det ikke er mulig master mĂ„ler ‱ Sampling for PVT. Representative sampling points . ‱ FĂžr oppstart skal mĂ„lere testes bĂ„de dynamisk og […] … Continue reading

08 Denstad Idriftsettelse Av Fiskale MĂ„lestasjoner Og PĂ„fĂžlgende OverfĂžrig Til Driftsorganisasjon

[…] grunn av manglende kompetanse − Manglende oppfĂžlging og involvering av leverandĂžrer/kontraktĂžr − «armer og bein» like fĂžr oppstart – mer regel enn unntak? − Oppstart med u testĂ„ende ting -> Ăžkte kostnader − Burde vi ha krav til kompetanse for utfĂžrelse av commissioning ? ‱ Bestilling og oppfĂžlging av leveranse ‱ Reservedeler, commissioning og […] … Continue reading

Scaling Turbin Basert OljemÄling

[…] i Prover umuliggjĂžr kalibrering f or lasting/eksport av olje . Dette er noe operatĂžrene pĂ„ Norsk sokkel allere de gjĂžr (programmer for Ă„ forutse mulig forekomst, samt testing av forskjellige kjemikalier for Ă„ forhindre forekomsten), men kanskje leverandĂžrene ogsĂ„ skulle vĂŠrt tilstedevĂŠrende i denne fasen? Hist orier der personell har hakket lĂžs biter pĂ„ […] … Continue reading

NFOGM Innspill Standardisering Desember 2013

[…] refererte standarder er stĂžrst mulig grad fjernet og er nĂ„ pĂ„ et minimumsnivĂ„. – Kravene er sĂžkt formulert mest mulig presise og mĂ„lbare – Normativt Annex for test ing er noe omarbeidet og gir testkrav til pĂ„ system – og komponent – nivĂ„. – Krav til stabilitets testing av gasskromatograf er satt ned fra […] … Continue reading

NSFMW Program Final

[…] Fiscal purposes – Field experience Bjarne Syre, DONG E&P Norge, Ole Andersen, Maersk Oil, Steinar Fosse, NPD 1400 2 performance of Subsea Multiphase Meters and a Topside test Separator during Well testing, after Skarv field start-up Barbara M. Wrobel, Lukasz H. Wrobel, BP Norge AS, Norway Andrew Hall, BP Exploration Operating Company Ltd, UK. […] … Continue reading

Poster 1 E Vehte OneSubsea

[…] field development plan to commence many years after the exploration phase, which was the time when the first samples were taken, either downhole or at the well test separator. Although details of the sample may have been recorded precisely, fluid compositions, properties and characteristics might have changed. As a result, assumptions are often made […] … Continue reading

Brown Gregor Calibration, Adjustment, Fluid Dependency And Long Term Stability Of Liquid Ultrasonic Meters

[…] 600 700 800 Flowrate (m3/hr) Error (%) Gas Oil Kerosene CALDON ULTRASONICS TECHNOLOGY CENTRE CALIBRATION LABORATORY PITTSBURGH, USA ‱ Prover ‱ Master meters ‱ Heat exchanger ‱ Test meter lines ‱ 7.5 ton bridge crane ‱ Main control room Main laboratory area Calibration fluids ‱ Refined hydrocarbon oils ‱ Oils chosen to give a […] … Continue reading

Drejer Harald Driftserfaringer Fiskale Coriolis MĂ„lere PĂ„ Nyhamna, Ormen Lange

[…] Harald Drejer MĂ„leteknisk ansvarlig, AS Norske Shell Copyright of Shell Brands International A G INNHOLD OG FORMÅL  MĂ„lestasjon for kondensat  Historikk  MĂ„leavvik  Kvalifikasjons test  Erfaringer  Kalibreringshistorikk  Videre plan  LĂŠrepunkter 2 19.03.2015 Copyright of Shell Brands International A G KONDENSATMÅLESTASJON – NYHAMNA, ORMEN LANGE 3 19.03.2015 Copyright […] … Continue reading

Probability Distributions And Divisors For Estimating Measurement Uncertainty By Rick Hogan

[…] used probability distribution for evaluating Type A data. If you do not know what Type A data is, it is the data that you collect from experimental testing, such as repeatability, reproducibility, and stability testing. To get a better understanding, imagine you are going to collect 100 measurement samples and create a histogram graph […] … Continue reading