Search Results for "RhMSUS Online Training Materials 🐔 RhMSUS Test Questions 🏌 RhMSUS Test Questions 👿 Search for ➥ RhMSUS 🡄 and easily obtain a free download on ⮆ www.pdfvce.com ⮄ 🐹RhMSUS Latest Test Vce"

2018 15

Calibrating and Testing Custody Transfer Hydrocarbon Liquid Meters. T. Cousins OGM by Denmark House, St. Thomas PlaceEly, Cambridge, CB7 4EX, UK+44 1353 666640www.oilandgasmeasurement.com Calibration & Type Testing • Calibration – The comparison of two methods, one of which is an accepted standard , using measurement uncertainty of the methods to define that comparison (It […] … Continue reading

D1 01 Dennis Van Putten DNV GL

[…] of oil degassing or gas carry -under • Provide correction for potential systematic biases on liquid flow • Assess a potential alternative metering system • Approach: • Test of an 8” helical turbine meter (Faure Herman TZN200) at DNV GL multiphase test facility under two -phase and mild multi -phase conditions (GVF<12%) • Selected […] … Continue reading

Andreassen Alf Magne, Sammenlignende Laboratorieprøving (SLP) Vann I Olje

[…] internt • OD følger opp mot selskapene 5 Grunnlag for SLP og deltakere • Grunnlaget for den vurderte målestørrelsen “Vann i råolje” er gitt ved den standardiserte testmetoden ASTM D 4928 for “Water in Crude Oils by Coulometric Karl Fisher Titration . (first edition 1989 – active edition 2000) • Deltagerne er personell som […] … Continue reading

Lessons Learned From Industrial Field Allocation Studies

[…] Mass or volume or calorific value? – Allocation principle (pro -rata, by -difference, phase -split based on simulated ORFs or measurements) • System modelling – Metering stations, test separators – Gas lift, water injection, gas injection • Input data both for host and tie -ins : What is available and what must be estimated? […] … Continue reading

09 Ghasemi M, Production Allocation Of Commingled Fluids Using Geochemistry

[…] IsoSleeve removed • PLT failed to indicate the contribution of Sand 1 during shut -in period of Sand 2 Case Study 3: North Slope 29 Page: Blind Test Measurement Case Study 4: North Slope Source: SPE144618: Stratum, Mark A. McCaffrey et al. 30 Page: Important • If end members are similar in their profile, […] … Continue reading

22 Comparison Of A Liquid Clamp On Flowmeter Vs Turbine Meter For Separator Oil Measurement AkerBp Xsens

[…] from 8’ to 4’ for the measurement section -Include a 4’ clamp –on meter -Provide space for a new 4’ turbine meter prov ided by AkerBP – Test the whole setup including new piping, clamp –on meter, and turbine meter in 2 different independent flow labs with satisfactory results before installation offshore This presentation […] … Continue reading

1982 05 Turbine Meters For Gas Bellinga N V Nederlandse Gasunie

‘ . • ‘K. V. l’EDERL/,NUSE G ASUNlE DEPARTMENT PLANNING AND RESEARCH TURBINE METERS FOR GAS. by H. Bellinga -. ~APPORT TP/lD 82. R.226 2 juni 1982 Doc. 1038L/0056L .. TP/ID 82. R.L.26 -2 – 1. Introduction The history of the turbine me~er for gases goes back to the beginning of this century. At […] … Continue reading

1987 05 Flare Gas Metering By Ultrasonic Measurement Hammer Fluenta

[…] the complete range of velocities occurring in the flare pipe. It should be non-intrusive to avoid errosion or clogging of the sensor elements, thus reducing the necessity for frequent calibrations. All of these objectives can be obtained by using an ultrasonic meter. but there are many technical difficulties which have to be solved to […] … Continue reading

1992 12 AGA Transmission Measurement Committee And The Revision Of AGA Report No 8 Stuart Pacific Gas And Electric

I — I I I I I it I I I I Ie I I I I I II I THE Nl A TRANs-ITSSIOO ME’ASUREMENl’ CXMIITI’EEANDTHEREVISIOO OF NlA REPORT No8CXMPRESSIBILITY FJC’IORSOFNATURAL GAS by J Stuart, Pacific Gas and Electric, J Savidge, Gas Research Institute and S Beyerlein and E Lamon, University of Idaho Paper […] … Continue reading

13 Using Subsea Multiphase Flow Metering Data For Remote Charachterization Of Fracking Fluid Containing Liquid Phase OneSubsea M. Darab

[…] reservoir engineer has a relatively clear picture of how the new stream contributes to the PVT properties of the reservoir fluids. The formation and production of solid materials such as scales (Bertrand, Ségéral , and Moksnes 2001 ) or sands (Pinguet , Hopman , et al. 2013) ( Bifout , Pinguet and Rojas 2014) […] … Continue reading

D3 01 MB Holstad JB Kok NORCE

[…] agreements) – Example: • Ultrasonic or Coriolis meter as duty meter • Turbine meter as master meter, regularly calibrated against a small volume prover. • Density from online densitometer. • Off –and on -loading process carefully regulated and monitored • Two coriolis meters in rotation with regular calibration at flow loop • Would not […] … Continue reading

Åbro Eirik, MUFA (Multifase Analysator)

[…] • • • Process Export Topside Subsea template A Oil producer Gas producer Oil/gas producer Water injector Spare Subsea template B Subsea template C Subsea template D Test separator MPFM MPFM Subsea MPFM on each producer Subsea SPFM on each injector • Case: High input error 10% density errors 5% salinity error Case: Reduced […] … Continue reading

Nytt Fra NFOGM 1 2005

[…] mars Interesante foredrag med påfølgende årsmøte. Etter årsmøte ble god mat og drikke servert. Under har vi gjengitt noen bilder fra arrangementet. “Bjørn Ullebust Statoil forteller om Online GC vedlikehold” ” Svein Neumann gratulerer Else Dahl Tekna med sitt jubileeum” ” Foreningen takker Steinar Fosse, OD og Trond Hjorteland, Statoil for innsatsen i styret” […] … Continue reading

Nytt Fra NFOGM 3 2010

[…] desember hos Tekna i Oslo I denne utgaven av nyhetsbrevet vil alle innlegg væ re linket til dokumentet. En kan også nå linken via vår hjemmeside www.nfogm.no ONLINE ANALYSE OG KONDISJONERINGSYSTEM – KRITISKE MOMENTER Av Bjørn Å. Bjørnsen , Process Control AS http://www.nfogm.no/docup/dokumentfiler/ONLINEAN ALYSE-KRITISKEMOMENTER.pdf ”PROVEN TECHNOLOGY” Av Ragnvald Soldal, Statoil http://www.nfogm.no/docup/dokumentfiler/ProvenTe chnology.pdf Maximising Platform […] … Continue reading

Nytt Fra NFOGM 3 2007

[…] inklusiv: o Et hus inneholdende H2S analysator, Dugg-punkts analysere sam t Prøve behandlings system o Trykkreduksjons system i en separat kabinett Leveringsom fang Tampen består av: • Online Gass analyse system i et hus m ed gasskrom atograf, duggpunktsm ålere og H2S analysatorer. Utstyret skal installeres i revisjonsstansen på Gullfaks A i 2008. • […] … Continue reading

Nytt Fra NFOGM 3 2006

[…] sitt første møte etter sommerferien på Kongsberg den 14. september hos FMC metering as. Av saker som ble behandlet på møtet kan nevnes: – Temadagen og Årsmøte for 2007 er satt til 16. mars i Oslo. Komiteen består av Kåre Kleppe, Dag H. Flølo og Flemming Sørensen. De tar med glede imot innspill til […] … Continue reading

Standarisering Status Juni 11.pdf

[…] Bidra aktivt til utvikling og bruk av nasj onale/industri standarder (NS/NORSOK) som dekker det identifiserte gapet mellom internasjonale standarder og det norske behovet. • Et effektivt system for forslag og erfaringstilbakeføring Effektiv standardi seringsvirksomhet • Sikre effektiv og fokusert bruk av ekspertgrupper fra industrien • Sikre effektiv og fokusert ledelse, orga nisering og arbeide […] … Continue reading

RS Densitet Artikkel NFOGM

[…] som svinger med sin egen resonansfrekvens og som opprettholdes gjennom pådrag sendt til en elektromagnet / drivspole. For å oppnå høyest mulig nøyaktighet i de tilfeller en online densitet må ler er installert i et fiskalt mengde måle sy stem bør påfølgende punkter gis spesiell oppmerksomhet.  Operasjonsområde må være innenfor de grens er […] … Continue reading

03 Erfaring Og Status Fra Oljeselskaper V Sidsel Corneliussen, BP Norge

[…] data og info. – Gode konsentrasjons og prioriterings evner dersom landskap. – Allokere ”front” – og ”back” office funksjoner. • Front office : Daglige oppfølging av målestasjonene online / ”brannslukking”/ daglige oppgaver. • Back office : Oppgaver med tidsperspektiv. IOE – Status Valhall og Hod i dag • CCR offshore • Kommunikasjons linjene sentrert […] … Continue reading

06 Fiskalmåling Av Olje Med Høy Vannfraksjon V Kjell Eivind Frøysa, CMR

1 Fiscal metering of oil with high water fraction. Sensitivity study for a turbine meter – based metering station Kjell-Eivind Frøysa, Anders Hallanger and Per Lunde Christian Michelsen Research AS,Bergen, Norway Presented at NFOGMs Temadag 2007, Rica Grand Hotell, Oslo, Friday March 16, 2007 2 Contents ■ Introduction ■ Objectives and project plans ■ […] … Continue reading